2014年2月20日星期四

The problems of the industrial autoclave’s operating time

Industrial autoclave is widely used in pipe pile, aerated concrete block, lime-sand brick, fly ash brick and other new building materials of high temperature and high pressure pipe, used to improve strength and excellent properties of the product.In the process of using, if the following problem, should take active measures to maintenance:
Corrosion of reaction caldron in the aeroconcrete production:
Corrosion on the harm of reaction caldron in the aeroconcrete production is quite big, not only can damage components, shorten service life of reaction caldron in the aeroconcrete, serious still can cause autoclaved kettle safety accidents.Common corrosion mainly aerobic corrosion and electrochemical corrosion, so you need to take the booster before sucking air in the kettle, the discharge of condensed water in time, regular cleaning tank bottom sediments and other measures to reduce the harm of corrosion.
Safety interlock reaction caldron in the aeroconcrete damage:
In the previous article, small make up for everybody introduced Zheng Guo autoclaved kettle safety interlock, safety interlocks of reaction caldron in the aeroconcrete production to avoid the operator can not decide whether or not the pressure in the kettle is zero wrong operation, greatly avoid the safety accidents.But when the safety interlock is damaged, cannot have the effect of protection, so in use after a period of time should check whether the device is work in a timely manner.
Above is of high efficiency and energy saving autoclaved kettle manufacturers Zheng Guo container, the analysis given in the next article, continue to introduce use of reaction caldron in the aeroconcrete production enterprise to problems arising from the use process, and found the problem, find ways to cope with the problem.
Kettle lid closed reaction caldron in the aeroconcrete production is easy:
If the perpendicularity of the kettle body flange is better, but by adjusting the kettle lid gearbox positioning screw nut, the kettle cover face about 5 mm lower than the upper outward tilt (as shown in figure 4).If the kettle body flange end verticality is larger, should readjust make it into the vertical or lower slightly tilted (no more than 2 mm).
Autoclaved kettle mechanical damage:
Products and maintenance vehicles in and out of the kettle in the process of wire rope or chain and other metal parts and kettle wall collision or scratch.Mechanical damage in addition to make the kettle body wall thickness thinning, and could accelerate the corrosion rate.As a result, those inside the kettle using wire rope or chain traction rope autoclaved kettle, should add spacing between track layout in the kettle hanging from the kettle bottom rollers, traction rope direct contact with the body to work.
Crack of reaction caldron in the aeroconcrete production:
Autoclaved kettle are found on the crack for the fatigue crack, the most common of which are still crack root department, with the structure of reaction caldron in the aeroconcrete production characteristics, and the running situation of carry alternating load, used as a unit is hard to avoid the cracks.Stress concentration of tank (e.g., nozzle), also can produce fatigue crack,
Autoclaved kettle foundation sink:
Autoclaved kettle used in foundation subsidence is one of the reasons for the improper design or construction, sinking position no rules to follow;Condensed water discharge is not timely, the bottom of the kettle and the kettle over 40 , the temperature difference between the top body will start on the arch deformation (over 70 ℃ could kettle body material yield and damage), the result is based on both ends of the sink.
ZGproduction safety and reliability and longer service life, welcome to choose and buy.

2014年2月10日星期一

The precautions should be paid to the coal fired boiler

ZGs experts through many years of experience in production practice, summed up the boiler fire up precautions:
1. Boiler firing range in 2 ~ 3 hours.
2. It should be adjusted according to the situation after ignition burning, uniform furnace temperature ascension and guarantee the heat balance of pressure components.
3. The detailed observations before the fire boiler components, each part of case maintenance immediately.
4. During the fire, economizer exit water temperature below 95 , within the prescribed temperature, should be on open big economizer to boiler pipe valve, also can increase the circulation pump, increase the water flow province coal tao.
More coal fired boiler you can click the link to have more information : http://www.zgindustrialboiler.com/product/chain-grate-boilers/list_2_1.html

Some maintenances method of industrial autoclaves

As the development direction of modern construction technology, autoclaved aerated concrete block is widely used, because of its good thermal insulation, earthquake resistance and non-radioactive, bearing, etc.
But how to learn the correct method of curing reaction caldron in the aeroconcrete production makes the body more safe and reliable?
Small make up for your detailed answers now:
1. In autoclaved curing process, pay attention to fit inside the kettle air, in order to make sure the pressure in the kettle is pure pure steam pressure, steam or close to chemical reactions needed to ensure the mixture of temperature.
2. Slowly heat up evenly, make the pressure inside the kettle to gauge pressure, effectively prevent the tile cracks caused by temperature stress.
3. Pay attention to the autoclaved curing period, when the steam pressure to zero in the kettle is its temperature and pressure under 70 , can open the kettle door out of bricks.If use table 1.0 MPa to 1.2 MPa pressure steam pressure to curing block, the constant temperature time can be shorten, 4.5 h ~ 6 h can achieve the required strength, also greatly improve the utilization of reaction caldron in the aeroconcrete production
More information about industrial autoclave you can login the website : http://www.zgindustrialboiler.com/product/autoclave/list_31_1.html 

2014年1月19日星期日

The better maintenance of biomass fired boiler

As PM2.5 arouse people's attention, the original high pollution of fossil fuel is criticized by people gradually, over the past few years the rise of biomass pellet fuel for its clean pollution-free, sources, low prices by the favour of people, and therefore promote the great development of industrial biomass boiler.
Biomass burning biomass pellet fuel boiler, the combustion time is long, enhanced combustion chamber of a stove or furnace temperature is high, and economical, without any pollution to the environment at the same time, the CO zero emissions, SO the zero emissions, renewable energy, can be recycled, can replace wood, coal, natural gas.And running cost is only half the fuel gas, has significant economic and social benefits.
And other forms of industrial boiler, biomass boiler in the process of long-term use, also pay attention to the boiler corrosion maintenance work, to reduce boiler corrosion, prolong its service life.With rich experience in industrial boiler manufacturing ZG related engineer gives the following Suggestions:
Furnace body external anti-corrosion maintenance:
Stop at biomass boiler furnace cooling, heating surface must be thoroughly remove dust and upper grate, furnace bottom ash.And then to keep the flue has certain natural ventilation.In general, for the sake of moisture should be placed in the chamber of a stove or furnace, flue desiccant, such as lime as a desiccant.
The inside of the furnace body corrosion maintenance:
For the interior of the biomass boiler maintenance, according to the length of the furnace.In general, the furnace is not more than a month of wet maintenance are available, and more than a month of dry method should be taken to maintain.Now is the cold winter, if use wet maintenance should pay attention to prevent frostbite, especially the drainage channels and economizer.
ZGbiomass boilers can prevent or solve the biomass combustion and heat transfer in the process of formation and slagging problem, and a long-term and stable operation.Flue gas emissions meet the relevant national standard of environmental protection, low ash carbon content, can realize the comprehensive utilization of fly ash.
Biomass fired boiler manufacturer : www.biomassfiredboiler.com 

2014年1月16日星期四

How to select the better industrial autoclave?

Autoclaved kettle is for new building materials such as gas, coal ash brick, block, pile microporous calcium silicate board, the new light wall material for high temperature and high pressure pipe of large pressure vessel.As the national policy for energy conservation and emissions reduction vigorously implement, more and more buildings began to use new building materials to reduce costs, improve the living environment, protect the environment, more and more manufacturers invest new building materials production, so how to select the type of reaction caldron in the aeroconcrete in investments to make it more conform to the principle of economy, the most competitive prices.
The following will introduce how to choose the most competitive prices industrial autoclave ?
The effective length of reaction caldron in the aeroconcrete and kettle inside diameter size
At the time of selection, choose appropriate to the size of the autoclaved kettle can not only meet the needs of the production of the enterprise, also can save unnecessary expenses.Customers can according to their own annual production of aerated block or the size of the quantity of pipe pile length and diameter suitable autoclaved kettle.For example of 5 cubic aerated block production line with annual output of 10 cubic used by the size of reaction caldron in the aeroconcrete certainly is not the same, the bigger cost is high.
The maximum working pressure of reaction caldron in the aeroconcrete production
In production, the maximum working pressure of reaction caldron in the aeroconcrete said it can withstand the maximum load, in general, autoclaved kettle wall are more, the working pressure, the greater the load utility is stronger, the higher the price, of course.When the choice, should according to own century requires the rated working pressure.
Autoclaved boo boo startup mode of the door
Kettle door startup mode refers to the operation in the process of how to open the door of the kettle into the way of pipe products.Traditional way of kettle door start with human is given priority to, not only time-consuming, also prone to accidents, in order to solve this problem, Zheng Guo container has developed a high degree of automation of full automatic hydraulic, pneumatic, electric) to open the door, reaction caldron in the aeroconcrete realize low operation, also can remote control, open the light, smooth operation.Manual open autoclaved kettle price much lower than the high degree of automation of autoclaved kettle, customers can according to the actual demand and how much of the money kettle door model selection.
In the form of autoclaved boo boo door
there are two main types of reaction caldron in the aeroconcrete production the container kettle door: the side door autoclave reactor and opened the door on the autoclave reactor.Traditional forms of side door occupies large space area, covers an area of more than, cost relatively is high;On the door of reaction caldron in the aeroconcrete plant height requirement is not high, take up the space is small, less investment.Investment enterprise should according to the size of the plant area models were selected, and can reduce the price to the lowest.
The number of kettle door
Have a through type have a kettle is at each end (door) and end (kettle door at one end) in two forms, through type kettle door products into kettle time saving, high production efficiency, investment cost is high also, selection of customers according to actual situation.
AAC autoclave: www.zgautoclave.com 

How to prevent the chain grate coal-fired boiler explosion?

Long-term since, domestic industrial heat supply remains focused on industrial boiler, especially chain grate coal-fired boiler, the boiler fuel is coal, burning, burning way is the chain grate layer.In use process, if the improper operation or other reasons may release boiler explosion phenomenon, cause the enterprise huge personal and property safety.
Zheng Guo as a leader in research and development of domestic chain grate coal-fired boiler design, in addition to providing the high quality of boiler products, also help customers to use in the process of any problems, in order to avoid the form of boiler explosion and its relevant engineer gives the following advice:
Paying attention to the quality of the chain grate coal-fired boiler when the choose and buy:
Good will reduce by half the explosion probability of boiler.If you choose to the boiler, must choose domestic well-known brand of large boiler or import boilers.Reason is very skillful, large boiler factory inspection strictly, high pass rate.Zheng Guo, for example, has 69 years of experience in industrial boiler manufacture, has professional r&d team of boiler, first-class production line, the chain grate coal-fired boiler with high reliability, high safety and strong overload capacity, high thermal efficiency, etc. The product is the best design of domestic similar products.
Secure attachment should not be ignored:
The safety of the chain grate coal-fired boiler accessories mainly include safety valve, pressure gauge, water level gauge, explosion-proof door, drainage device, temperature measuring device, such as boiler accessories is a sign that the boiler operation and reduce the possibility of boiler explosion is an important part of.
Regular inspection and maintenance:
Periodically chain grate coal-fired boiler operation condition, methods of removal of boiler scale, at the same time improve the quality of the stoker are also necessary measures to reduce boiler explosion safety concerns.People-oriented, full play to the role of the boiler work is very important.

2014年1月15日星期三

What is the working principle of industrial autoclave?

There are a lot of customers on the working principle of reaction caldron in the aeroconcrete .customer often ask "how is reaction caldron in the aeroconcrete work", "what is the working principle of reaction caldron in the aeroconcrete?".
Today, small make up for this common problem, customers to focus in industrial autoclave manufacturer-ZG give the answer:
Airtight sex is a very strong reaction caldron in the aeroconcrete large pressure vessel, and autoclaved kettle Zheng Guo production equipment is given priority to with quick open autoclaved kettle, its rated working pressure and steam temperature of pipe products (such as aerated concrete block, aerated brick and pipe pile, gypsum, etc.) is a very important impact.In the need of pipe products after a certain high temperature and pressure, made within the kettle Cao - Si02 - H2O water fluid, so the mixture of siliceous react with calcium, obtain certain intensity and performance, aerated block output to meet the requirements, aerated brick, etc., meet the needs of the market, brings to the enterprise profit and value.
Working principle of reaction caldron in the aeroconcrete production is more easy to understand, mainly for the maintenance of inside the kettle, including heating, constant temperature, temperature and three phases, the pros and cons of various properties of aerated concrete block, mainly depends on the discretion of the curing temperature (pressure), and the length of the curing time. High temperature (pressure), full reaction, various performance are better. At the same time, the brick curing at high temperature, maintenance time required to get the same intensity can be reduced.
Zheng Guo container, welcome friends from all walks of life to visit our factory and consulting the choose and buy hotline at 0371-86678499
Industrial autoclave for sale: www.zgautoclave.com